Protecting Wood Door Thresholds with Recessed Contacts
Edwards Signaling 12th Dec 2022
Protecting Wood Door Thresholds with Recessed Contacts APPLICATION For wood doors with aluminum thresholds, it is sometimes convenient to mount the magnet in the bottom of the door and the switch in the hollow space beneath the threshold. Note: Because of the distance between the magnet and switch, a Sentrol wide gap switch should be used. INSTALLATION Select a recessed-mount wide gap Interlogix switch. Drill horizontal hole for magnet in outside edge of door. Coat magnet with RTV mo
…