750-833/025-000 WAGO 750 Series Programmable Logic Controller (PLC) CPU Unit w/ Extended Temperature Range

Image may represent a range of products. Product may vary based on listed specifications.

WAGO 750 Series Programmable Logic Controller (PLC) CPU unit with extended temperature range, 16-bit processor, 63 x connections per node + 96 x fieldbus mode on the controller (master) connection capability, with PROFIBUS communication capability, supply voltage 18-31.2Vdc via wiring (24Vdc nom.), with 9-pin D-sub connector (fieldbus) + cage-clamp 2-pin (system), DIN-35 rail mounting (71.1mm width), IP20, rated for -20°C...+60°C ambient, equivalent to 750833025000.

  • Manufacturer: WAGO
  • Product Family: 750 Series
  • Product Category: Controllers
  • Product Type: Programmable Controllers
  • Ambient air temperature for operation: -20°C...+60°C
  • Ambient air temperature for storage: -40°C...+85°C
  • Ambient temperature (operation): -20 | +60 °C
  • Analog inputs quantity: no analog inputs
  • Analog outputs quantity: no analog outputs
  • Approvals for marine applications additional text: -|-|DNV-CG-0339,Aug.2021|-|-
  • CPU: 16 bits
  • Communication protocol: PROFIBUS
  • Conformity marking: CE
  • Connection capacity: 63 x connections per node|96 x fieldbus mode on the controller (master)
  • Connection type (electrical) (filter / rank = 0005030): D-Sub connector|Terminals (Cage-clamp)
  • Current carrying capacity (power jumper contacts): 10A
  • Current consumption (5 V system supply): 200mA
  • Data memory: 64 KB
  • Degree of pollution: 2
  • Degree of protection: IP20
  • Depth: 71.1 mm / 2.799 inches
  • Depth from upper-edge of DIN-rail: 63.9 mm / 2.516 inches
  • Digital inputs quantity: no digital inputs
  • Digital outputs quantity: no digital outputs
  • Dimensions: H100mm x W50.5mm x D71.1mm
  • Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
  • Fine-stranded conductor: 0.08 | 2.5 mm² / 28 | 14 AWG
  • Fire load: 2.61MJ
  • General approvals additional text: TP TC 020/2011|Article 58-2, Clause 3|UL 508
  • Height: 100 mm / 3.937 inches
  • Housing Material: Polycarbonate; polyamide 6.6
  • Humidity: 95% relative humidity (RH; non-condensing)
  • Input and output process image (fieldbus) max.: 244 bytes/244 bytes
  • Input current (typ.) at nominal load (24 V): 500mA
  • Isolation: 500 V system/field
  • Material: Polycarbonate (PC) / Polyamide (PA) 6.6 housing
  • Memory for fieldbus input variables (max.): 244Byte
  • Memory for fieldbus output variables (max.): 244Byte
  • Mounting mode: DIN rail
  • Mounting position: any
  • Net Width (mm): 71.1mm
  • Non-volatile software memory: 8Kbytes
  • Number of fieldbus nodes on master (max.): 96
  • Number of modules per node (max.): 63
  • Number of outgoing power jumper contacts: 3
  • Pollution degree (5): 2 per IEC 61131-2
  • Power supply efficiency (typ.) at nominal load (24 V): 0.87
  • Processor type: 16-bit processor
  • Program memory: 128 KB
  • Protection type: IP20
  • Relative humidity (without condensation): 0.95
  • Shock resistance: 15g per IEC 60068-2-27
  • Solid conductor: 0.08 | 2.5 mm² / 28 | 14 AWG
  • Speed: 9.6kbit/s-12Mbit/s
  • Supply voltage (DC): 18-31.2Vdc via wiring (24Vdc nom.)
  • Supply voltage (DC): 24Vdc
  • Surrounding air temperature (storage): -40 | +85 °C
  • Total current (system supply): 1,800mA
  • Vibration resistance: 4g per IEC 60068-2-6
  • Visualization: none
  • Weight: 187.5g
  • Width: 50.5 mm / 1.988 inches
  • Connection type (electrical): D-Sub connector|Terminals (Cage-clamp)

750-833/025-000
Frequently bought together: